1Form# 42708-0120120210©2012 Hunter Fan Co.Set & $aveSet & $aveSet & $aveinstallation andoperation manualModels4415544157 Programmable

Page 2

10GRCRHY Wif your existing thermostat is marked...label the wire with this sticker:G / FGGW / H / BW/BW/BY / C* / M / OY/0Y/0RC / VCRCRCRH / R / VR /

Page 3 - TABLE OF CONTENTS

114. Using the provided stickers, label each wire according to the chart. • If the terminals are not labeled, contact a qualied HVAC technician. •No

Page 4 - Set & Save

12WRCYGINSTALLING THE THERMOSTAT

Page 5

13INSTALLING THE WALL PLATE1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2. Position t

Page 6

14WRCYG

Page 7

154. Remove the wall plate and drill two 3/16” holes where marked. 5. Tap the plastic anchors into the holes until they are ush with the wall. 6. Rep

Page 8

16GRCRHY/0W/BRCGY1Y/0W/BY1Terminal ShieldCONNECTING THE WIRES

Page 9

171. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not

Page 10 - GRCRHY W

18DISABLEENABLERECOVERYHGHEW/B Y/O RH RC GSYSTEM TYPESTDHPY1FAN OPTIONAMHEAT4TThermostat CoverSystem SwitchG RC RH Y/O W/B Y1ATTACHING THE THERMOSTAT

Page 11

19Lift the thermostat cover and set the SYSTEM switch to OFF and the FAN switch to AUTO. 1. Locate the HE/HG switch on the back of the thermostat. Se

Page 14

214. Place the top of the thermostat over the two tabs on the wall plate. Press the thermostat onto the wall plate and press to snap the bottom tab in

Page 15

22resetSETTINGS

Page 16 - Terminal Shield

23The default setting of the thermostat is Fahrenheit (Fo). NOTICE: CHANGING THIS SETTING WILL RESET THE THERMOSTAT TO FACTORY DEFAULT PROGRAMS. (If

Page 17

24day/timeAMPM

Page 18 - ATTACHING THE THERMOSTAT

25The default for this thermostat setting is in a 12 hour format. You can change the format to 24 hour format by pressing Day/Time and then Program. T

Page 19

26AMHEAT4T

Page 20

27This thermostat gives you the ability to program up to 4 custom temperature settings per day or utilize pre-programmed settings. For manual operatio

Page 21

28AMHEAT2THMANUAL OPERATION

Page 22 - SETTINGS

29Many people prefer to operate their thermostats manually, adjusting settings as needed. You can either temporarily override the settings for the cur

Page 23 - Reset button

3Important Information... 5Tools ... 6 Uninstalling t

Page 24

30hold/returnsystemoffheatcoolHOLD

Page 25

31If you want to permanently override all settings and adjust the thermostat manually:1. Press Hold/Return until the Hold icon appears. 2. Press and h

Page 26

3210 pm8 am6 amProgram 1Heat : 68o F (20o C)Cool : 78o F (26o C)Program 2Heat : 60o F (16o C)Cool : 85o F (29o C)Program 3Heat : 68o F (20o C)Cool : 7

Page 27 - METHODS OF OPERATION

33By using the pre-programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling.After setting the time an

Page 28

34AMPMprogramhold/returnsystemoffheatcoolCREATING CUSTOM PROGRAMS

Page 29 - Up or Down for one second to

35• Program times can be set in 10 minute increments.• Program temperature can be set in increments of 1o F (1o C).• After 15 seconds of inactivity

Page 30

36AMPMHEATCOOLSA2134SUMTWTHFprogramhold/returnsystemoffheatcool

Page 31 - Hold/Return to return to the

373. Press Up or Down to change the hour. Press Program to save the hour and adjust the minute setting. 4. Press Up or Down to change the minute. Pres

Page 32

38FILTERfilterICONS AND FEATURES

Page 33

391. INDIGLO® Night-Light - will backlight the display for easy viewing in the dark. Press any button to illuminate the light. (If no button is pres

Page 34

4Congratulations!Thank you for choosing a Hunter programmable thermostat. Your new Hunter thermostat will provide years of reliable service and year-r

Page 35 - LCD will begin to ash)

40HEAT COOLsystemoffheatcoolreset

Page 36 - HEATCOOL

413. Span setting mode – allows you to adjust the system ON/OFF cycle rate. The default setting is 2 (the system cycles ON or OFF when the temperature

Page 37

42PMCOOL4MSTAGE 1STAGE 2

Page 38 - ICONS AND FEATURES

434. Low battery warning – indicates two stages of battery power shortage. When the batteries are detected as weak, the icon will ash until new AA

Page 39

44hold/return

Page 40 - HEAT COOL

455. Auto recovery – allows heating and cooling systems to gradually recover from an energy-saving setpoint temperature to a comfort setpoint temperat

Page 42

476. Error mode – indicates an unexpected battery problem. The screen will ash an ERR message and shut your system off until the batteries are replac

Page 43

481. Temperature Range2. Compressor ProtectionAfter the system stops running in cooling mode, there will be a 3.5 minute delay before it can be restar

Page 44

491. My display will not come on. • Check batteries and battery connections. • Reset the thermostat. ...

Page 45 - Temporary holds are on.)

5This thermostat is designed to work on the following heating and cooling systems:Gas – Standing PilotGas – Electronic IgnitionGas – Fired BoilersGas

Page 46

505. My heating or cooling will not turn on or off. 5 a. Check the Heat/Cool function switch to ensure it is set to the desired position. 5 b. Wait. T

Page 47

517. My system continues to operate when the thermostat is in the off position. 7 a. Replace unit. ...

Page 48 - "LO"

52Is there help on the web? Yes. Visit http://www.HunterFan.com for more information. ...

Page 49

6This thermostat includes two #8 slotted screws and two wall anchors for mounting.To install your new thermostat, you will need the following supplies

Page 50

7NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ens

Page 52 - Can I just call someone?

91. Turn the system power OFF from the existing thermostat. Turn the power to the HVAC system OFF at the main power panel or at the furnace. 2. Remove

Commentaires sur ces manuels

Pas de commentaire