www.HunterFan.com1.888.830.1326PAGE7PAGE13PAGE14PAGE10PAGE5PAGE17PAGE630 inches7 feetPAGE2What to Expect with Your InstallationCeiling BracketLadderPA
www.HunterFan.com1.888.830.1326WiringFROM FANFROM CEILING BRACKETFROM FANUsing an orange wire connector from the hardware bag, connect the 3 gr
www.HunterFan.com1.888.830.132611M0042-01 • 11/12/12 • © Hunter Fan CompanyCanopyLift the canopy into place so that the screw holes are aligned. Posit
www.HunterFan.com1.888.830.1326BladesYour blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. For cleaning the fa
www.HunterFan.com1.888.830.1326Feed the wire plug through the center hole of the upper switch housing, then wrap keyhole slots around the screws and t
www.HunterFan.com1.888.830.1326Connect the plugs from the upper and lower switch housings. Make sure to line up the colored markings on the connectors
www.HunterFan.com1.888.830.1326Light Kit (continued)CONGRATULATIONS!YOU’RE DONE!Install a bulb into each of the sockets. When necessary, replace with
www.HunterFan.com1.888.830.1326M0042-01 • 11/12/12 • © Hunter Fan Company16Maintenance & CleaningThe fan pull chain controls the speed: high, medi
www.HunterFan.com1.888.830.1326M0042-01 • 11/12/12 • © Hunter Fan Company17Troubleshooting Excessive wobbling• Tighten all of the blade and blade
www.HunterFan.com1.888.830.1326M0042-01 • 11/12/12 • © Hunter Fan CompanyWhat to Expect with Your InstallationKnow your wiringIf you are unfamiliar wi
Tools NeededLadderPower Drill (optional)9/64” Drill Bit (optional)ScrewdriversPliers Wire StrippersIf mounting to a support structure, you will also n
www.HunterFan.com1.888.830.13264M0042-01 • 11/12/12 • © Hunter Fan Company4M0042-01 • 11/12/12 • © Hunter Fan CompanyIf you have an angled ceiling:1.
1.888.830.1326www.HunterFan.comCeiling BracketOFFMake sure all four (4) bumpers are still attached.For angled ceilings, point opening toward peak.Refe
www.HunterFan.com1.888.830.1326Ceiling Bracket (continued)Preparation1.888.830.1326www.HunterFan.comDISCARDKEEP!Remove the shipping blocks from the mo
1.888.830.1326DownrodSlideSlide1 2 3 4 5678910Sold SeparatelyIncludedLonger Downrodfor angled ceilings or ceilings 10’ or higherShorterDownrodfor fans
KEEP!8”3/8”CUT& STRIP(not to scale)Remove the pre-installed setscrew so that the downrod can be inserted.Hand tighten the downrod (at least 4-5 fu
1.888.830.13269M0042-01 • 11/12/12 • © Hunter Fan Companywww.HunterFan.comDownrod (continued)DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES. Place the
Commentaires sur ces manuels